Installation types

Common types of installations

Every home and unit is a little different. Here's what to expect from the most common air-conditioning installations we carry out across Townsville — from replacements to new back-to-back installations.

Example only: dirty indoor and outdoor split-system units before cleaning, next to the same units after a professional clean
Example of a split-system aircon replacement.

Type 01

Back-to-Back Replacement Installation

A standard replacement of a split-system air conditioner, carried out back-to-back with the indoor and outdoor units on opposite sides of the same wall. Here's what the work typically involves.

Inside

  • Decommission and remove the old indoor head unit
  • Install the new head unit in the existing location
  • Connect it to the interconnects and drain

Power

  • Reuse the existing electrical circuit and connection point
  • Install an isolation switch beside the outdoor unit if one is absent

Outside

  • Decommission and remove the old compressor and reclaim its refrigerant gases
  • Mount the new outdoor unit on existing wall brackets if suitable
  • Run up to 3 metres of copper piping between the units if required
  • Existing piping may be reused if suitable or beneficial
  • Connect and commission the new system

This is a general guide to a back-to-back replacement. Reuse of existing brackets, ducting, drain and pipework requires installer approval. If existing wiring does not meet current standards, or other work is needed, the customer will receive a quote before work proceeds and can decide whether to go ahead.

Possible extra charges

These charges may apply depending on your home and are confirmed before any work begins.

  • Two-storey installation
  • Each additional metre of copper piping
  • Additional travel outside 30 km from the store

Additional or replacement ducting, electrical conduit, unsuitable or missing brackets, and unforeseen extras will be quoted if needed.

Painting & patching

Painting and patching are not included. A smaller new head unit may leave an area requiring patching or painting. The installer is not responsible for pre-existing electrical or structural issues.

Installation guarantee

Installation work completed is covered for five years from the original installation date. For replacement installs, the guarantee covers only new work and new components — not reused existing components. The air conditioner itself is covered by the relevant manufacturer's and statutory warranties.

Example only: indoor and outdoor air-conditioning units installed on opposite sides of the same wall
Example of a split-system aircon replacement.

Type 02

Back-to-Back New Installation

A standard new split-system installation carried out back-to-back, with the indoor and outdoor units on opposite sides of the same wall.

Inside

Inside: measure and install the bracket, interconnects and indoor unit. Make the required penetration holes through timber, plasterboard or another hollow-cavity wall.

Power supply

Power supply: run a power feed from the switchboard, with an allowance of 16 metres through the ceiling and up to 4 metres of external conduit. Install a circuit breaker (RCBO) in the switchboard if required, provided a DIN-mount position is available. Install a new isolation switch beside the outdoor unit.

Outside

Outside: install new powder-coated brackets to support the outdoor unit, a new condensate drain of up to 3 metres, and up to 3 metres of copper piping between the indoor and outdoor units. Install duct cover and capping to protect the copper pipes. Connect and commission the system.

This standard scope is a general guide to a back-to-back installation. If additional work is needed, the customer will receive a quote before work begins and can decide whether to proceed. Existing wiring may not meet current standards; if so, the installer will explain the issue and quote the required work before proceeding.

Possible additional charges

  • Two-storey installation above ground floor
  • Copper piping beyond the included 3 metres
  • Travel outside 30 km from the store
  • Specialist coring through solid block or concrete
  • New switchboard panel-mount enclosure if the DIN mount is full

Additional ducting or conduit, and unforeseen extras: quoted before installation proceeds.

Painting and patching

Painting and patching are not included. The installer is not responsible for pre-existing electrical or structural issues that affect installation.

Installation guarantee

Installation work is covered by a five-year guarantee from the original installation date. The guarantee applies to installation work, while the air conditioner is covered by the relevant manufacturer's and statutory warranties.

Example only: indoor head unit mounted on an internal wall with copper piping and ducting running to an outdoor compressor on a different wall
Example of a back-to-side split-system installation.

Type 03

Back-to-Side New Installation

A new split-system installation where the indoor head unit is not back-to-back with the outdoor compressor, but is instead located on an internal wall. Because the two units sit on different walls, this installation includes more labour, additional ductwork and a longer run of copper piping to connect them.

Inside

Inside: measure and install the bracket, interconnects and indoor head unit on an internal wall — not on the same wall as the outdoor compressor. Because the head unit is not back-to-back with the compressor, the interconnects and drain must travel further to reach the outside, requiring additional ductwork and a longer run of copper piping.

Power supply

Power supply: run a power feed from the switchboard, with an allowance of 16 metres through the ceiling and up to 4 metres of external conduit. Install a circuit breaker (RCBO) in the switchboard if required, provided a DIN-mount position is available. Install a new isolation switch beside the outdoor unit.

Outside

Outside: install new powder-coated brackets to support the outdoor unit, a new condensate drain of up to 3 metres, and an extended run of copper piping between the indoor head unit on the internal wall and the outdoor unit on a different wall. Install additional duct cover and capping to protect the longer copper pipe run. Connect and commission the system.

This standard scope is a general guide to a back-to-side installation. Because the head unit is on an internal wall, the job typically requires more labour, additional ductwork and a longer copper piping run than a back-to-back install. If further work is needed, the customer will receive a quote before work begins and can decide whether to proceed. Existing wiring may not meet current standards; if so, the installer will explain the issue and quote the required work before proceeding.

Possible additional charges

These charges may apply depending on your home and the length of the pipe run, and are confirmed before any work begins.

  • Two-storey installation above ground floor
  • Copper piping beyond the included allowance for the longer internal-wall run
  • Additional duct cover and capping for the extended pipe run
  • Travel outside 30 km from the store
  • Specialist coring through solid block or concrete
  • New switchboard panel-mount enclosure if the DIN mount is full

Additional ducting or conduit, and unforeseen extras: quoted before installation proceeds.

Painting and patching

Painting and patching are not included. The installer is not responsible for pre-existing electrical or structural issues that affect installation.

Installation guarantee

Installation work is covered by a five-year guarantee from the original installation date. The guarantee applies to installation work, while the air conditioner is covered by the relevant manufacturer's and statutory warranties.

Example only: 3D cutaway of a house showing insulated copper piping running up into the ceiling space, across the roof and down to the outdoor unit
Example Only

Type 04

New Up and Over Installation

What is an Up and Over installation?

An Up and Over installation is used when the best position for the indoor aircon unit is some distance from the outdoor unit, often on the other side of the house. Instead of connecting the units through the wall directly behind the indoor unit, the insulated copper pipes run up into the ceiling space, across the house and down the outside wall to the outdoor unit.

Why does it cost more than a standard installation?

This type of installation involves working in the ceiling space, a longer run of copper piping and more time to route, secure and connect the system. The amount of work depends on the distance between the units, access to the ceiling space and the layout of the home.

We'll assess the route and provide a quote for the additional materials and labour before the installation proceeds. The final route is subject to what our installer finds on site.

Not sure which type you need?

Tell us about your existing system and rooms in the quote builder. We'll recommend the right installation type for your home — free and with no obligation.

Quote my Aircon
Licensed technician installing an outdoor air-conditioning unit